Skip to content
GATEiit

GATE DA · Probability and Statistics

Central limit theorem

The sampling distribution of the sample mean and sum, the central limit theorem and when it applies, the normal approximation to binomial and Poisson counts with continuity correction, and sample-size calculations.

Before you start

This topic comes before: Approximate inference through sampling, Confidence intervals; z-test, t-test and chi-squared test

Concept notes

1. The sample mean and its standard error

Let X1,…,Xn be i.i.d. with mean μ and variance σ2. The sample sum Sn=∑Xi and sample mean Xˉ=Sn/n satisfy E[Sn]=nμ,Var(Sn)=nσ2,E[Xˉ]=μ,Var(Xˉ)=σ2n. The SD of Xˉ, σn, is called the standard error (SE). To halve the SE you need four times the sample size.

These facts need only independence and a finite variance, not normality. Note that the SD of the sum grows like n while the SD of the mean shrinks like 1/n.

The law of large numbers says Xˉ→μ as n→∞: the average settles at the true mean. The CLT goes further and describes the shape of the fluctuations of Xˉ around μ.

2. The central limit theorem

Central limit theorem (CLT): if X1,X2,… are i.i.d. with mean μ and finite variance σ2>0, then for large n Zn=Sn−nμσn=Xˉ−μσ/n  ≈  N(0,1). Equivalently, Xˉ≈N ⁣(μ,σ2n) and Sn≈N(nμ,nσ2), whatever the shape of the original distribution.

What to remember:

  • It is the mean or sum that becomes normal, not the individual data.
  • If the population is itself normal, Xˉ is exactly normal for every n.
  • How large is "large"? About n≥30 is the usual rule of thumb; skewed populations need more, symmetric ones fewer.
  • The finite-variance condition matters: for a Cauchy distribution (no finite variance) the sample mean never becomes normal.

The diagram shows means of exponential samples: at n=1 the density is the skewed exponential, at n=4 it is still skewed, and at n=16 it is close to a bell centred at the mean with SD 1/4.

01 (mean)23solid: n = 16dashed: n = 4dotted: n = 1 (exponential)
Density of the mean of n Exp(1) samples: skewed at n = 1, nearly normal and narrower at n = 16

3. Normal approximation to binomial and Poisson

A binomial count is a sum of n independent Bernoulli variables, so the CLT gives Bin(n,p)≈N(np, np(1−p)),good when np≥5 and n(1−p)≥5. Similarly Poisson(λ)≈N(λ,λ) for large λ (since a Poisson count is a sum of many small independent counts).

Continuity correction. A count takes integer values, but the normal is continuous. Treat the integer k as the interval [k−0.5,k+0.5]:

Count event Use the normal for
X≤k X<k+0.5
X<k X<k−0.5
X≥k X>k−0.5
X=k k−0.5<X<k+0.5

Example: 100 fair coin tosses, P(X≥60). Mean 50, SD 5. With correction, z=59.5−505=1.9 and P≈1−Φ(1.9)≈0.029. Without it, z=2 gives 0.023, a noticeably worse answer. Apply the correction only to discrete counts, never to sums of continuous variables.

4. Using the CLT: probabilities and sample size

Recipe for a probability:

  1. Decide whether the question is about a sum Sn or a mean Xˉ.
  2. Write its mean and SD: nμ and σn, or μ and σ/n.
  3. Standardise and read Φ (with continuity correction for counts).

Example: fill volumes have mean 500 ml and SD 10 ml. For a sample of 25 bottles, SE =10/5=2, so P(Xˉ>504)=1−Φ(2)≈0.023.

Sample size for a given precision. To have P(∣Xˉ−μ∣≤E)≈1−α, require zα/2σn≤E⟹n≥(zα/2 σE)2, and round up. For 95%, z0.025=1.96; for 90%, 1.645; for 99%, 2.576.

This is also why confidence intervals for a mean have the form Xˉ±z⋅σ/n: they invert the CLT statement.

Formulas to remember

Mean and variance of the sample mean
E[Xˉ]=μ,Var(Xˉ)=σ2n
Standard error
SE=σn
CLT for the mean
Xˉ−μσ/n≈N(0,1)
CLT for the sum
Sn−nμσn≈N(0,1)
Normal approximation to binomialUse when np≥5 and n(1−p)≥5; apply continuity correction
Bin(n,p)≈N(np, np(1−p))
Sample sizeRound up
n≥(zα/2 σE)2

Common mistakes

  • Using σ instead of σ/n when the question is about a sample mean (or σn for a sum).
  • Claiming the CLT makes the individual data normal; only sums and means become approximately normal.
  • Forgetting the continuity correction for binomial or Poisson counts, or applying it to continuous data.
  • Rounding the required sample size down; always round up.
  • Applying the normal approximation to a binomial with np<5; use the exact binomial or a Poisson approximation.

Worked examples

Try each step yourself, then reveal the working.

Example 1: Average fill volume

numerical

A machine fills bottles with mean 500 ml and SD 10 ml. For a random sample of 25 bottles, find the probability that the sample mean exceeds 504 ml. Use Φ(2)=0.9772.

  1. Step 1: Find the standard error.

    Try it on paper first.

Example 2: Coin tosses with continuity correction

numerical

A fair coin is tossed 100 times. Approximate the probability of at least 60 heads. Use Φ(1.9)=0.9713.

  1. Step 1: Find the binomial mean and SD.

    Try it on paper first.

Example 3: How big a sample?

numerical

A population has SD 12. How large a sample is needed so that the sample mean is within 2 of the population mean with probability 0.95?

  1. Step 1: Write the CLT condition.

    Try it on paper first.

Example 4: What exactly becomes normal?

conceptual

Delivery times are exponential (strongly right-skewed) with mean 30 minutes. A manager records 50 delivery times. Which is approximately normal: the 50 recorded times, or their average? What are the mean and SD of the approximating normal?

  1. Step 1: Apply the CLT statement carefully.

    Try it on paper first.

Previous year questions

2 official GATE DA questions on this topic, newest first.

Practise these 2 PYQs →

Topic test

10 questions: up to 2 official PYQs and original practice questions, with GATE marking (MCQ wrong answers lose marks). Score 60% or more to pass. A new set is drawn each time.

Mark as mastered

Loading your progress…

My revision notes

Notes written by the GATEiit team against the official GATE DA syllabus; being checked by a reviewer. Updated 2026-11-21. Spotted a mistake? Use Report an issue on any question, or contact us.